INSTALLATION INSTRUCTIONS R−410A Ductless Split System Air Conditioner and Heat Pump MODELS: DLC4(A/H)−Outdoor, DLF4(A/H)−Indoor SIZES: 9K, 12K, 18K, 24K, 30K, and 36K NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE PARTS LIST.................... 1 SAFETY CONSIDERATIONS............ 1 GENERAL.....................

2 SYSTEM REQUIREMENTS............. 2 ELECTRICAL TABLES............... 2 DIMENSIONS................... 3 CLEARANCES...................

7 INSTALLATION.................. 8 INDOOR UNIT INSTALLATION............ 8 Install Mounting Plate.............. 8 Drill Hole in Wall for Connecting Piping,Drain&Wiring.9 OUTDOOR UNIT INSTALLATION........... 9 Piping and Drainage Connections.........

• Override—This option allows the access point to operate in high-power mode without first verifying a matching MAC address. Air-pwrinj4 installation guide guide.

Mitsubishi SRK25GZ-L1 handbook online. Wall mounted type. SRK25GZ-L1 Air Conditioner pdf manual download. Also for: Srk35gz-l1, Srk502z-l1. Sat, 22 Dec 2018 19:10:00 GMT MITSUBISHI SRK25GZ-L1 HANDBOOK Pdf Download. - To access the updated Vendor Information Pages(VIP) you must select one of the. Mitsubishi SRK35GZ-L1 Pdf User Manuals. View online or download Mitsubishi SRK35GZ-L1 User Manual.

9 Control and Power Wiring from Outdoor Unit... 10 AIR PURGING AND LEAKAGE TEST........ 11 START−UP.................... 12 OPERATION TEST................

Mitsubishi

12 AIR FILTER INSTALLATION............ 12 CONNECTION DIAGRAMS.............

13 TROUBLESHOOTING............... 14 The following parts are included in your indoor unit. Please contact your dealer if any parts are damaged or missing. Mounting Plate 1 Remote Control 1 Remote Control Holder 1 Mounting Hardware 7 Battery (1.5V) 2 SAFETY CONSIDERATIONS Installing, starting up, and servicing air−conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location (roofs, elevated structures, etc.). Only trained, qualified installers and service mechanics should install, start−up, and service this equipment.

Untrained personnel can perform basic maintenance functions such as cleaning coils. All other operations should be performed by trained service personnel. When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment. Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth and fire extinguisher nearby when brazing.

Use care in handling, rigging, and setting bulky equipment. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. In Canada, refer to current editions of the Canadian Electrical Code, CSA 22.1.

Recognize safety information. This is the safety−alert symbol!!. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety−alert symbol.

DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage.

NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.

Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label.! CAUTION EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Do not bury more than 36 in. (914 mm) of refrigerant pipe in the ground. If any section of pipe is buried, there must be a 6 in.

(152 mm) vertical rise to the valve connections on the outdoor units. If more than the recommended length is buried, refrigerant may migrate to the cooler buried section during extended periods of system shutdown. This causes refrigerant slugging and could possibly damage the compressor at start−up. 4 00 10/01/12 INSTALLATION INSTRUCTIONS R−410A Ductless Split System: DLF4(A/H), DLC4(A/H) GENERAL These instructions cover the installation, start−up and servicing of DLC4(A/H) outdoor and DLF4(A/H) indoor units ductless systems. SYSTEM REQUIREMENTS Allow sufficient space for airflow and servicing unit.