5 Quality QUALITY OMVL is a Company certified with a Quality System ISO 9001:2000. This certificate, released by TUV Italy - which belongs to the German Group TUV Suddeutschland - is related to the entire process of designing, manufacturing and marketing of gas components and complete fuel supplying systems for gas-propelled vehicles. OMVL Company processes are defined, monitored and subjected to programs of constant improvements in order to reach high goals in efficency and effectiveness which guarantee a continuous and increasing consumer satisfaction of our products branded REG.
EmmeGas Systems = (PRO-USB) LPG,CNG,GPL,Autogas Programming. EMMEGAS ECU 07 LPG GPL CNG AUTOGAS USB FTDI Interface Kit + SOFTWARE. AUTRONIC (MISTRAL 1 & 2) EMMEGAS (Ics-03, Ecu-07, Emer Frank) ZANARDI. DVD with Software, manual and drivers. LPG Connector must look like this.
Download ace the ielts book pdf free shared files from DownloadJoy and other world's most popular shared hosts. Our filtering technology ensures that only latest ace the ielts book pdf files are listed. Download ace the ielts ielts general module pdf download free shared files from DownloadJoy and other world's most popular shared hosts. Our filtering technology ensures that only latest ace the ielts ielts general module pdf download files are listed. Ace the ielts pdf full download full. Download Ace the IELTS by Simone Braverman PDF eBook free. The “Ace the IELTS: IELTS General Module – How to Maximize Your Score 3 rd Edition” is a great book with all advice need to pass the IELTS exam. Description of Ace the IELTS by Simone Braverman PDF. Ace The ielts PDF is a popular academic book for ielts which includes all the essentials and tips related to ielts. This book is widely used by students who are going to take the ielts test. It covers all the sections of ielts test and makes you able to get your self-prepared for the test in a few weeks.
REG products are subjected to a process control for the entire manufacturing course which starts from in-coming material control to final tests under pressure performed on the production as a whole in accordance with the international and internal Regulations in order to guarantee and maintain continually a high standard of quality and safety. The LPG and CNG converting components are approved in line with the European Regulations R67 01 and R110. Moreover, the CNG converting components are approved in accordance with ISO Regulation.
REG converting systems for small, medium and high power engines are approved in line with the European standards for emissions of pollution Euro4. 5 6 6 spa 7 Introduction MINIMUM COMPUTER REQUIREMENTS FOR SOFTWARE INSTALLATION Operating system.
Windows 98 SE or later Memory (ram): Mbytes at least Hard disk: Mbytes of free space at least Screen resolution: x 600 or better Internet Explorer version 5.5 or later should also be installed INSTALLING THE SOFTWARE When you are ready to install the software, insert the cd-rom in the computer and wait for the installation wizard to pop-up. Should the wizard fail to start, click the Start button in the Applications Bar and select Run. Enter: D: setup.exe (where D is your Cd-rom drive). You will be asked to choose a directory where the software will be installed; we recommend to choose the default one. Once the installation has been completed, the icon of the program will be automatically put on your desktop. INTRODUCTION It s not necessary to connect the ECU to start the software. However, if you want to program the ECU, you need to connect the it to the PC with an interface cable, part number OMVL (not supplied in the kit, should be ordered separately).
Furthermore, the control unit must be powered by the +12 V battery voltage (via the red-black wire) and properly grounded (black wire). 8 Main Menu This menu is used to access all the submenus contained in the software, all of which are listed and described below: The following information is provided at the bottom of the page: (1) (2) (3) (4) 1) This indicates if the control unit is connected or not connected to the PC. It is important to remember that any settings made when the control unit is not connected will be lost at the time of connection, unless they have been already saved in a configuration file.
The program will automatically attempt to connect to the control unit when you open it. If the program can t connect to the ECU, a window will pop-up reporting an error. You should check: - the connection of the serial interface, - the connection of the control unit to the battery and to ground, - if the key has been switched off for more than an hour, you should switch it on for a few seconds or crank-up the car, if the switch doesn t light up with the instruments. To attempt a connection again, open the Connection menu at the top of the window and select Connect. 2) This is the name that can be given or has been given to the configuration of the vehicle; for a new control unit, the standard configuration is standard LPG. The control unit must be connected to the configuration software in order to download an existing configuration into the control unit.
3) This is the version of the control unit s software; select the ECU REPROGRAMMING sub-menu to update it. Note: this is only possible if INTERNET EXPLORER version 5.5 or later is installed on your PC. 4) This indicates if the current configuration downloaded into the control unit uses the operating parameters for CNG or LPG; go to the VEHICLE CONFIGURATION sub-menu to select the type of fuel. 9 Vehicle configuration This sub-menu is made up of 7 pages (when the REG009 dongle-key is plugged into the PC) where you can change the parameters that define the behaviour of the gas control unit. These parameters must be set according to the signals that are present on the vehicle.